CB35 DOMESTIC CEILING BATTEN
ROLLFORMERS SUPER-SPAN CB35 Ceiling Batten has been designed to provide a sound framework to fix boards for fibrous plaster & gib board installations to timber frame constructions. Its lightness, strength, dimensional accuracy and stability overcome problems associated with timber framing. See also our battens cut to length service

Some superior features of the CB35 steel Battens are.
-
Strength
-
Stability
-
Dimensional Accuracy
-
Lightweight
-
Ease of handling
-
No movement
-
No moisture
-
No nail popping
Manufactured from 0.55mm galvanised steel (275g/m2 Zinc) G250.Z275 to NZS 3441: 1978
No secondary products required.
Safety edge folding for easy handling
Safety and location pattern to resist screw slipping.
CB 35 Ceiling Batten
BATTEN SPANS AND SPACINGS
Span |
Maximum
Spacings |
Maximum Uniformly
Distributed Load Kg/m2 |
900 |
450 |
60 |
|
650 |
47 |
1200 |
450 |
37 |
|
650 |
27 |
At the spans designated above the ceiling battens will support all proprietary ceilings with the additional of a 0.5 Kpa line load hence meeting NZS 4203: 1992 Table 3.4.1 Category 1 , Domestic 1.1. All deflections are within 1500of span , Ie 2.5mm for 1200mm span and 2mm for 900mm span. For specific design requirements involvingextraordinary loadings, e.g. heavy light fittings,contact the Manufacturers Technical Department.
CB 35 Ceiling Batten
NOTES ON PRODUCT HANDLING, STORAGE AND USE
Battens should be stored in a dry, flat area to ensure that the product is not distorted,scratched or damaged. Should moisture damage occur, the product should be separated and dried. Failing to do this could impair the life of the galvanised coating.
Battens should not be used in corrosive atmospheres or in contact with tanalised timber, copper products or chemically treated products (e.g. insulation)
If used in a roof situation, a thermal barrier should be used over the batten. Generally installation of the battens should not proceed until the building has been closed off. However the CB35 batten has pre-punched holes along the length that will allow draining of any moisture collected in the batten.
Special attention should be paid to all electrical wiring regulations .
PLEASE NOTE: Rollformers 2000 LTD strongly recomends the use of electrical strapping to earth across all steel batten on installation. This would prevent any possibility of the battens going live on contact with a power source.
Additional CB35 Products
CB35 - Batten Clips - Used to drop the ceiling batten down from the bottom of the roof trusses , allowing accurate adjustment of final ceiling level . Brackets designed to side fix on roof trusses with slotted fixing holes allowing vertical adjustment .
CB35 - Perimeter Channel - Used when no ribbon plate attachment is available this odd leg channel is placed around the perimeter of the ceiling area allowing support for the CB35 battens on their outer edges.